A commercial, light
industrial system designed to provide waterproofing and insulation
with a durable wearing surface. By reducing extreme temperature
differentials, both heat gain and thermal shock are limited.
APPLICATION
PROCEDURE
- Sprayed-in-Place
Insulation - Urethane foam insulation shall be two component,
sprayable type specifically manufactured for roof insulation.
| a. |
Apply
insulation to all low, ponding areas to reduce standing
water.
space |
| b. |
Spray
apply 1 " average 2-1/2 or 3 lb. density foam over
all roof areas to seal and insulate the substrate.
Insulation shall be carried up all adjacent vertical
surfaces to waterproof roof/wall junctures. Additional
foam insulation may be applied to taper and enhance
drainage and/or to provide greater R-value. |
- Fluid Applied
Waterproofing
| a. |
Spray
apply 60% solids DURAGARD Acrylic Elastomer coating over
insulation at a rate of 1-1/2 gallons per 100 square feet.
space |
| b. |
Spray
apply application of 60% solids DURAGARD Acrylic Elastomer
coating at 1/1/2 gallons per 100 square feet using a white
color.
space |
| c. |
Embed
Shasta aggregate at the rate of 30-35 Lbs. per 100 square
feet onto wet top coat to provide wearing surface. |
NOTE: This
system possesses high strength-to-weight ratio, weighing
approximately 70% less than a comparable asphaltic roof. It
locks the roof deck together with a monolithic barrier to heat and
moisture. It is adaptable to any configuration upon which it
is sprayed. |